Product Classification
5 MWh liquid-cooled containerized energy storage system
Product Number:
SZXH-YN-1331/5M
Battery Cell Model:
3.2V/314Ah
Battery Specifications:
1P416S
Nominal Voltage:
1331.2V
Nominal Capacity:
5.01 MWh
Charging Voltage:
1331.2V
Charging Current:
0.5P
Discharge Current:
0.5P
Instantaneous Discharge Current:
0.5P
Application Areas:
Industrial energy storage
Finished Product Internal Resistance:
≤200 mΩ
Battery Weight:
<43T
Product Dimensions:
L6200×W2550×H2896mm
Charging Temperature:
0~55℃
Discharge Temperature:
-20~55℃
Storage Temperature:
-30℃ to 50℃ (>45℃ derating)
Temperature Protection:
55℃ ± 5℃
Battery Case:
Cold-rolled sheet metal
Lithium Battery Protection:
Short-circuit protection, overcharge protection, over-discharge protection, overcurrent protection, temperature protection
The 5 MWh liquid-cooled containerized energy storage system is a containerized energy storage solution specifically designed for industrial and commercial energy storage applications. It incorporates advanced technologies such as lithium iron phosphate (LiFePO4) and boasts the following core advantages:
Cost reduction and efficiency improvement
Flexible deployment
Safe and reliable
Intelligent Operation and Maintenance
Category:
Industrial energy storage
Keywords:
Product Introduction
Reduce costs and improve efficiency: Liquid-cooling thermal management reduces system auxiliary power consumption and simultaneously extends battery life; semi-integrated design—simple installation and easy debugging.
Flexible deployment: Using standardized containers allows for integrated transportation and lifting, with no geographical limitations. Pre-commissioning reduces on-site integration work, enabling rapid grid connection, simple installation, and easy commissioning.
Safe and reliable: Electrical components and batteries are housed separately to prevent the spread of thermal runaway; reliable disconnection within microseconds reduces short-circuit current by 75%; at the PACK level, fire suppression using perfluorohexanone is employed, coupled with combustible gas detection and ventilation systems; water-based fire suppression is available as an optional feature.
Intelligent Operations and Maintenance: Local EMS + cloud platform for online intelligent monitoring, enabling minimal staffing and digital operations & maintenance; self-diagnosis of faults, remote troubleshooting and upgrades;
Product Parameters
Model |
Voltage |
Capacity |
Battery level |
Rated power |
Depth of discharge |
Waterproof rating |
Operating temperature |
Warranty period |
5 MWh liquid-cooled containerized energy storage system |
1331.2V
|
5MWh |
5MWh |
2507kW
|
95% |
IP55 |
-20~55℃ |
5 years |
Basic Cell Parameters
Project |
Specifications |
Note |
Cell model |
LFP-MB31
|
/ |
Cell type |
Square battery |
/ |
Nominal capacity |
314 Ah |
0.5P/0.5P, (25
±2)℃,
2.5V~3.65V fresh
Battery
|
Nominal energy |
1004.8 Wh |
|
Nominal voltage |
3.2 V |
/ |
Charging termination voltage |
3.65 V |
/ |
Discharge termination voltage |
2.5V (T > 0°C) 2.0 V (T ≤ 0°C) |
(25 ± 2)℃
|
Maximum instantaneous charging current |
0.5p |
/ |
Battery pack combination form |
1P416S |
|
Serial number |
Security risk |
Protection Policy |
1 |
Overvoltage |
BMS
:
Report when a Level 1 alert is triggered.
PCS
Alert: Reduce charging current and power.
Report when a Level 2 alert occurs.
PCS
Prohibited from charging
Report when under Level 3 protection.
PCS
Fault, and the high-voltage box relay will be switched off after a certain period of time.
|
2 |
Overcurrent |
BMS(
Charging
)
:
Report when a Level 1 alert is triggered.
PCS
Alert: Reduce charging current and power.
Report when a Level 2 alert occurs.
PCS
Prohibited from charging
Report when under Level 3 protection.
PCS
Fault, and the high-voltage box relay will be switched off after a certain period of time.
BMS(
Discharge
)
:
Report when a Level 1 alert is triggered.
PCS
Alert: Reduce discharge current and power.
Report when a Level 2 alert occurs.
PCS
No firecrackers
Report when under Level 3 protection.
PCS
Fault, and after the filtering time, the high-voltage box relay will be switched off.
|
3 |
Short circuit |
a
)
PACK
When a short circuit occurs at the level,
PACK
The internal fuse withstands short-circuit currents and melts within a short period of time, ensuring that the short-circuit current is promptly interrupted.
b
) In the event of a short circuit at the cluster level, protection is provided jointly by relays and fuses within the high-voltage box. When...
SBMU
When the circuit current is detected to exceed the normal operating current, the relay’s holding voltage is cut off, triggering the relay’s trip action and disconnecting the main circuit. In the event of a large short-circuit current, since the fuse’s melting time is shorter than the relay’s trip response time, the primary function of disconnecting the main circuit is performed by the fuse.
C
) In the event of a system-level short circuit, by
MBMU
The electrically operated control disconnects the main circuit of the system.
|
4 |
Thermal runaway |
The cell is equipped with an explosion-proof valve, which serves to relieve pressure in the event of thermal runaway in the cell.
PACK
Equipped with an explosion-proof vent valve, when...
PACK
When the internal pressure is too high, to...
PACK
Perform pressure relief. The fire protection system is equipped with cluster-level detection capabilities and can be activated via the fire piping system.
PACK
The internal gas components are detected via intake sampling, and the cluster-level detector is multi-functional, equipped with...
CO
temperature sensor, smoke sensor,
VOC
Detection capabilities for various parameters. At the container level, it features temperature sensing, smoke detection, and combustible gas detection.
/
Carbon monoxide
/
Hydrogen detector, a detector that can also detect combustible gases.
/
Carbon monoxide
/
The hydrogen detector monitors the concentration in real time and reports it to the fire alarm control panel, equipped with...
PACK
The tiered fire sprinklers and piping can directly spray fire extinguishing agents into...
PACK
Internally, it can meet the requirements for extinguishing fires and continuously suppressing reignition. The fire protection system and...
BMS
System interlock: When the fire protection system outputs an alarm signal,
BMS
Can be controlled in a timely manner
PCS
、
BMS
Disconnect the high-voltage circuit.
|
5 |
Puncture |
PACK
There are upper and lower housing sections, equipped with puncture-resistant capabilities, which serve to protect the battery cells.
The container is externally protected to prevent external factors from affecting the interior.
PACK
Cause an impact.
|
6 |
Fall down |
PACK
Has undergone drop tests,
PACK
with the positive or negative terminal facing down from
1.2m
Falling freely from a height onto a cement floor.
1
Second, it doesn't catch fire and doesn't explode.
Inside the container, via battery racks.
PACK
Perform fixation, which can be effective.
PACK
Displacement occurs inside the container.
|
Related Downloads
Corporate Profile
Production Site
Advanced Equipment
Warehouse Overview
Global Sales Network
FAQ
Q
What types of new energy batteries do you mainly produce?
A
We focus on the production of lithium-ion and sodium-ion batteries, with products widely used in electric vehicles, energy storage systems, consumer electronics, and industrial equipment. Customized specifications are supported.
Q
Is this factory direct? Can I visit the production base?
A
We are an original factory (not a trading company) with our own production line and R&D team. Our production base is located in Building 8, Lithium Battery Industrial Park, High-tech Zone, Zaozhuang City, Shandong Province. On-site visits are welcome to witness the entire production process.
Q
How long is the shipping time?
A
- Domestic orders: 7-15 business days for standard products,
- International orders: Approximately 3-6 weeks depending on destination and customs clearance procedures;
- Custom orders require an additional 5-10 business days (as per contract confirmation).
Q
What payment methods are supported?
A
Alipay/WeChat (for small orders), bank transfer. For regular collaborations, a 30% deposit is required upfront, with the balance due before shipment.
Q
Has the product passed international quality certification?
A
All products have passed CE, RoHS, and UN38.3 certifications and comply with the ISO 9001 quality management system. Some models also have UL and IEC certifications.
Q
Do you offer OEM/ODM services? What is the minimum order quantity (MOQ)?
A
Supports customized development, with a minimum order quantity (MOQ) of 500 battery cells (standard products). Special specifications require evaluation and confirmation. Free sample testing is available (shipping costs are borne by the customer).
Q
What is your after-sales policy? How are quality issues handled?
A
- Warranty period: 2 years for battery cells, 1-3 years for finished battery packs (depending on the model);
- For non-human damage quality issues, returns, exchanges, or repairs are supported. A test report is required, and the after-sales team will respond within 24 hours.
Q
How can I check the battery's technical parameters or download the specifications?
A
The official website's "Product Center" section provides detailed technical documentation, or you can contact customer service to have the specified model information sent to your email address. Both Chinese and English versions are supported.
Q
What is the cooperation process?
A
① Requirements Communication → ② Solution Confirmation/Quotation → ③ Contract Signing → ④ Production and Quality Inspection → ⑤ Logistics and Delivery → ⑥ After-sales Tracking.
Q
How can I contact you for more information?
A
- Service Hotline: 0632-8663156 (Weekdays 8:00-17:00)
- Business Email: sales20@chinabatteries.com
Get a free quote
Please fill in your contact information and requirements, and we will arrange for a professional to contact you!